Hardware options installation 64
In a multiprocessor configuration, to optimize system performance, HP recommends balancing the total
capacity of the DIMMs across the processors.
To install the component:
1. Power down the server (on page 17).
2. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
3. Do one of the following:
o Extend the server from the rack (on page 17).
o Remove the server from the rack (on page 19).
4. Remove the access panel (on page 20).
5. Remove the heatsink blank.