EasyManua.ls Logo

HP ProLiant DL980 G7 - Server Specifications

HP ProLiant DL980 G7
112 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Server Specifications
ValueSpecification
Dimension
35.36 cm (13.92 in)Height
87.63 cm (34.5 in)Depth
48.26 cm (19.0 in)Width
93 kg (205 lb)Weight (maximum)
75 kg (165 lb)Weight (one hard drive, power supply and processor
installed)
Input requirement
1
100-240 VACRated line voltage
9.3A @ 100 VACRates input current
9.5A @ 108-120 VAC
6.6A @ 200-240 VAC
50–60 Hz +/- 3hzRated input frequency
4600 WInput power (maximum)
14,444 BTU/hr (worst case configuration and utilization)BTUs rating (maximum)
Power supply output (per power supply)
800 W @ 100 VACRated steady-state power
900 W @ 110-120 VAC
1200 W @ 200-240 VAC
950W @ 100 VACRated input power
1075W @ 108–120 VAC
1375W @ 200-240 VAC
960 W @ 100 VACMaximum peak power
1080 W @ 110-120 VAC
1440 W @ 200-240 VAC
1
To ensure the server has sufficient power during normal operation, a server configured with eight populated CPU sockets
or a detected high power GPU requires high line (200 - 240 V) ac server configuration. As a precaution, if these
configurations are detected on a low line (100 - 127 V) ac configured server the server will halt at Power-On Self-Test
with a "Low line (100-120 VAC) power delivery is not sufficient for this configuration. High line (200-240 VAC) delivery
is required to operate the system in its current configuration" message and only boot to RBSU.
At POST, the server automatically detects whether the power supplies are connected to high-line
power or low-line power. If the server is configured with eight populated CPU sockets or a detected
high power GPU, the system will halt if it detects that the server is plugged into low-line power.
This occurs by design because systems configured eight processors, and/ or high power graphics
cards, with a large amount of memory, hard drives, or other options might require more power
than can be provided by low-line power. POST halts this low-line configuration as a precaution
against the server having insufficient power during operation.
If a you wish to operate a server in this configuration when utilizing low-line power, the power
supply solution should be verified as sufficient using the HP Power Advisor (http://www.hp.com/
go/hppoweradvisor). If the power solution is not deemed sufficient, the server may not have
Server Specifications 105