5. Use the web interface to flash iLO.
6. Power on the system.
7. Boot the system to the OS.
8. If running, disable SNMP agents service.
For Windows operating systems:
Run Services.a.
b. Select SNMP Service.
c. Click Stop to stop the service.
d. Click yes to stop the services indicated.
For Linux operating systems, enter
service hp-snmp-agents stop
.
9. Flash the FPGA using the FPGA Smart Component.
NOTE: When updating the individual components, the Smart Components will detect if the
component is already at the correct revision by displaying the message pictured below. For
components other than is CPLD, you can select "Close" and continue with the rest of the
firmware update process. For the CPLD, you must select "install" and update the CPLD.
TIP: The estimated time for this update is 10 - 15 minutes.