EasyManua.ls Logo

HP ProLiant ML350 Gen9 - HPE Smart Storage Battery

HP ProLiant ML350 Gen9
124 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Removal and replacement procedures 42
2.
Power down the server (on page 29).
3. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
4. Extend the server from the rack (on page 29).
5. Remove the access panel ("Access panel" on page 33).
6. Remove the air baffle (on page 31).
7. Remove the fan cage (on page 31).
8. Disconnect the Systems Insight Display assembly cable from the system board. For more
information, see "System board components (on page 85)."
9. Remove the screws securing the Systems Insight Display assembly.
10. Remove the Systems Insight Display assembly.
To replace the component, reverse the removal procedure.
HPE Smart Storage Battery
To remove the component:
1. Do one of the following:
o For tower models, open and remove the tower bezel ("Remove the tower bezel" on page 28).
o For rack models, if installed, remove the security bezel ("Remove the security bezel (optional)"
on page 28).
2. Power down the server (on page 29).
3. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
4. Do one of the following:
o For tower models, place the server on a flat, level surface with the access panel facing up.
o For rack models, extend the server from the rack (on page 29).
5. Remove the access panel ("Access panel" on page 33).