Component identification 84
3
Amber = DIMM error
Off = Normal
4
Solid green = Link to network
Flashing green (1 Hz/cycle per sec) =
Network active
Off = No network activity
All other LEDs Off = Normal
On = Failed
Systems Insight Display LED combinations
When the health LED on the front panel illuminates either amber or red, the server is experiencing a
health event. Combinations of illuminated SID LEDs, the system power LED, and the health LED indicate
system status.
Systems Insight
Display LED and
Health LED
System power
LED
Status
Processor (amber)
One or more of the following conditions
might exist:
Processor in socket X has failed.
Processor X is not installed in the
socket.
Processor X is unsupported.
ROM detects a failed processor during
POST.
Processor (amber)
Processor in socket X is in a pre-failure
condition.
One or more DIMMs have failed.
DIMM in slot X is in a pre-failure condition.
Overtemperature (amber)
The Health Driver has detected a cautionary
temperature level.
Overtemperature (amber)
The server has detected a hardware critical
temperature level.
Fan (amber)
Fan has failed or is missing, but still meets
the minimum fan requirements.
Fan (amber)
Fan has failed or is missing and no longer
meets the minimum fan requirements.
Power supply (amber)
Only one power supply installed and in
standby mode.
Power supply fault.
System board fault.
Power supply (amber)
Redundant power supply is installed
and only one power supply is functional.
AC power cord is not plugged into
redundant power supply.
Redundant power supply fault.
Power supply mismatch at POST or
through hot-plug addition.