Chapter 4: Server troubleshooting 23
Table 1: Drive state events and alarms
Firmware state Tree view Event example Alarm
Physical drive S0SDNEABC01131
at slot:1 health state has changed
from Healthy to Failed.
HPE SimpliVity 380 Physical
Drive Health State Error
Failed Failed
Drive Set 0 in the SSD Array can
tolerate the loss of 0 more drive(s)
before the OmniCube fails.
HPE SimpliVity 380 SSD Array
Critical
Missing Missing Physical drive at slot:9 is missing.
Drive Set 0 in the SSD Array can
tolerate the loss of 1 more drive(s)
before the HPE OmniStack host
fails.
HPE SimpliVity 380 SSD Array
Warning
Physical drive S0SDNEABC01153
at slot:0 health state has changed
from Healthy to Offline.
HPE SimpliVity 380 Physical
Drive Health State Error
Offline Offline
Drive Set 0 in the SSD Array can
tolerate the loss of 0 more drive(s)
before the HPE OmniStack host
fails.
HPE SimpliVity 380 SSD Array
Critical
PredictiveFailure Healthy Physical drive S0SDNEABC01131
at slot:1 has experienced a high
number of predictive failures.
Replace it as soon as possible.
HPE SimpliVity 380 Physical
Drive Predictive Failure
Physical drive S0SDNEABC01153
at slot:0 health state has changed
from Offline to Rebuilding.
HPE SimpliVity 380 SSD Array -
Rebuilding the maximum number
of drives
Rebuild Rebuilding
(with a percent
complete)
The SSD array currently has 1
drive(s) rebuilding.
HPE SimpliVity 380 SSD Array
Critical
Physical drive S0SDNEABC01131
at slot:1 health state has changed
from Healthy to Failed.
HPE SimpliVity 380 Physical
Drive Health State Error
Unconfigured, bad Failed
Drive Set 0 in the SSD Array can
tolerate the loss of 0 more drive(s)
before the HPE OmniStack host
fails.
HPE SimpliVity 380 SSD Array
Critical
Unconfigured, good Unconfigured Physical drive S0SDNEABC01131
at slot:1 has a foreign
configuration.
HPE SimpliVity 380 Physical
Drive Health State Error