Chapter 4: Server troubleshooting 26
Server state LED 1 LED 2 Description
Off Flashing red (1 on,
1 off)
Field Programmable Gate Array (FPGA)
configuration error detected or configuration
failed.
Off Solid green
FPGA configuration is complete.
Off Flashing red
(2 on, 2 off)
Firmware is not responding to health check.
Flashing yellow
Solid green
Power-on self test (POST) is executing.
Solid yellow
Solid red
POST failed.
POST
Solid green Solid green
Normal operation (passed POST).
State save
Solid yellow
Flashing green
NVRAM state save is in progress.
State restore
Flashing yellow
Flashing green
NVRAM state restore is in progress.
Upgrade
Flashing green Flashing green
Firmware upgrade is in progress.
HostCtrl
Flashing yellow
Flashing red
Not in service. Contact Customer Support
(http://www.hpe.com/support/hpesc) for a
replacement.
Accelerator card not detected
If the server is unable to detect or communicate with an Accelerator card after you power on the server or perform
a server firmware upgrade, you see error conditions.
LED number Initial state Error state (Host Ctrl)
After power up After software upgrade1
Off
Solid green Off
2
Off
Solid yellow Flashing yellow
A firmware load error on the Accelerator card might have caused the problem. You can try to correct this problem: