Chapter 4: Server troubleshooting 26
Server state LED 1 LED 2 Description
 Off  Flashing red (1 on,
1 off)
Field Programmable Gate Array (FPGA)
configuration error detected or configuration
failed.
 Off  Solid green
FPGA configuration is complete.
 Off  Flashing red
(2 on, 2 off)
Firmware is not responding to health check.
 Flashing yellow
 Solid green
Power-on self test (POST) is executing.
 Solid yellow
 Solid red
POST failed.
POST
 Solid green  Solid green
Normal operation (passed POST).
State save
 Solid yellow
 Flashing green
NVRAM state save is in progress.
State restore
 Flashing yellow
 Flashing green
NVRAM state restore is in progress.
Upgrade
 Flashing green  Flashing green
Firmware upgrade is in progress.
HostCtrl
 Flashing yellow
 Flashing red
Not in service. Contact Customer Support
(http://www.hpe.com/support/hpesc) for a
replacement.
Accelerator card not detected
If the server is unable to detect or communicate with an Accelerator card after you power on the server or perform
a server firmware upgrade, you see error conditions.
LED number Initial state Error state (Host Ctrl)
After power up After software upgrade1
 Off
 Solid green  Off
2
 Off
 Solid yellow  Flashing yellow
A firmware load error on the Accelerator card might have caused the problem. You can try to correct this problem: