1. Shut down and power off the server.
2. Remove the replacement physical disk (the one undergoing a rebuild), and reinstall the disk
that is being replaced.
3. Power on the server.
If the newly failed disk seems to be operational again:
1. Back up unsaved data.
2. Remove the disk that was to be replaced, and reinstall the replacement disk. The rebuild
process restarts.
3. When the rebuild process finishes, replace the newly failed disk.
If the newly failed disk has not become operational:
1. Remove the disk that was to be replaced, and reinsert the replacement physical disk.
2. Replace the newly failed disk.
3. Restore data from backup.