Page #48 background image
Deleting a logical drive
To delete a logical drive that has been configured on a Smart Array Controller, use the command
saconfig /dev/cissX -D <Logical drive #>.
The following example deletes logical drive 0 from the Smart Array Controller with the device
filename ciss7:
# saconfig /dev/ciss7 -D 0
Are you sure you want to delete logical drive 0 on
SmartArray RAID controller /dev/ciss7? (y/[n]): y
Logical drive 0 deleted
WARNING! All data on the specified logical drive and the physical disks included in that logical
drive is lost when you enter the saconfig /dev/cissX -D <Logical drive #> command.
Deleting logical drives when multiple logical drives share physical disks
To avoid fragmentation when multiple logical drives share one or more physical disks, you must
delete the drives in reverse order of the logical drive number, from highest to lowest.
To determine the drive numbers, use the saconfig /dev/cissX command.
Example 3 shows the saconfig /dev/cissX command output for three logical drives that share
one physical disk:
48 Configuration

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP Smart Array HP-UX 11i v2 and is the answer not in the manual?

HP Smart Array HP-UX 11i v2 Specifications

General IconGeneral
BrandHP
ModelSmart Array HP-UX 11i v2
CategoryServer
LanguageEnglish

Related product manuals