2. To confirm that the correct firmware version is installed, use saupdate LIST. See “Verifying
the controller firmware” (page 26).
For example:
fs0:\EFI\TOOLS> saupdate list
************************************************************************
Smart Array Offline Firmware Update Utility
Version 2.07.09.02
(C) Copyright 2006 Hewlett-Packard Development Company, L.P.
************************************************************************
Seg Bus Dev Func Description Version
0 8 0 0 HP Smart Array P800 4.10
External Enclosures Connected :
Index Description Version
2 MSA70 2.06
HELP or ?
To display usage text, program version number, and build date, use HELP or ?:
Enter saupdate HELP
or
saupdate ?
Verifying the installation
After the system reboots, verify that the installation was successful by following these steps:
1. Enter the swlist command:
# swlist
If the Smart Array Controller is installed correctly, the generated output looks similar to the
following examples:
For HP-UX 11i v3:
RAID-01 B.11.31.0709.01 RAID SA; Supptd HW=A7143A/A9890A/A9891A
For HP-UX 11i v2:
RAID-01 B.11.23.0706 RAID SA; Supptd HW=A7143A/A9890A/A9891A
The version string that appears indicates the version of the RAID-01 bundle installed on your
server.
2. Enter the ioscan -kfnd ciss command:
# ioscan -kfnd ciss
If the Smart Array Controller software is installed correctly, the generated output looks similar
to this:
# ioscan -kfnd ciss
Class I H/W Path Driver S/W State H/W Type Description
==========================================================================
ext_bus 5 0/6/0/0/0/0/1/0/0/0 ciss CLAIMED INTERFACE PCIe SAS SmartArray P400 RAID Controller
/dev/ciss5
If the software is not installed correctly, reinstall it using swinstall. See “Installing software”
(page 24).
Confirming and updating physical disk firmware
To confirm and update the firmware version on each physical disk in the SmartArray disk enclosure
attached to the Smart Array Controller, use the sautil command.
Verifying the installation 33