Table 20 Smart Array controller POST error codes (continued)
Corrective actionLevelDescriptionError
code
Check the array configuration.CriticalSlot z Drive Array - Array Accelerator
Configuration Error. Data does not correspond to
this drive array
1795
Array Accelerator is temporarily disabled.
Check the cache module, and replace
if necessary.
CriticalSlot z Drive Array - Array Accelerator is Not
Responding.
1796
Array Accelerator is temporarily disabled.
The cache module has failed. Contact
your HP service representative for
assistance.
CriticalSlot z Drive Array - Array Accelerator Read Error
Occurred.
Data in Array Accelerator has been lost.
1797
Array Accelerator is disabled.
The cache module has failed. Contact
your HP service representative for
assistance.
CriticalSlot z Drive Array - Array Accelerator Self-Test
Error Occurred.
Array Accelerator is disabled.
1798
Press F1 to continue with logical drives
disabled. See Chapter 4 (page 59).
CriticalSlot z Drive Array - Drive(s) Disabled due to Array
Accelerator Data Loss.
1799
Press F2 to accept data loss and
re-enable logical drives.
Warning: Pressing F2 erases all data
in the array. Be sure you have a valid,
current backup of the affected logical
drives before selecting this option.
The cache module has failed. Contact
your HP service representative for
assistance.
Critical179A-Slot z Drive Array – Array Accelerator is
disabled Unknown Problem Code).
Array accelerator is temporarily (permanently )
disabled.
1799
POST error codes 115