EasyManuals Logo

HP Smart Array HP-UX 11i v2 User Manual

HP Smart Array HP-UX 11i v2
130 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #119 background imageLoading...
Page #119 background image
Table 24 Smart Array P411 controller specifications (continued)
NOTE: Support for greater than 2TB in a single logical drive.
64-bit, supporting servers memory space greater than 4 GBMemory addressing
RAID 5 (Distributed Data Guarding)RAID levels supported
RAID 1+0 (Striping & Mirroring)
RAID 0 (Striping)
Upgradeable Firmware with Recovery ROM featureUpgradeable firmware
256 MB (approximately 48 MB is used by the onboard processor)Cache size
Table 25 Smart Array P700m controller specifications
Type I, 4-port, PCIe mezzanine boardCard type
11.3 cm x 10.0 cm x 2.0 cm (4.5 in x 4.0 in x 0.8 in)Dimensions (excluding bracket)
Approximately 9.30 WMaximum power required
15 minutes to 2 hours, depending on initial battery charge levelTime required to recharge battery
More than 2 days, with fully-charged batteries that are less than 3 years
old
Duration of battery backup
More than three yearsBattery life expectancy
Spare battery part number
452348-B21 (for HP Integrity BL860c servers)
383280-B21 (for HP Integrity BL870c servers)
1 to 5 C (50º to 13 F)Operating temperature range
-30º to 60º C (-22º to 140º F)Storage/Shipping temperature range
10% to 90% (Storage/Shipping 5% to 90%)Operating relative humidity (noncondensing)
0, 1, 1+0, 5, 6 (ADG)RAID levels supported
108 externalMaximum number of physical drives (using
all four ports)
32Maximum number of logical drives
Up to 2 GB/s in each directionPCI Express transfer rate
Two external; each port has four 1x linksNumber of SAS ports
Up to 1.2 GB/s per port in each directionSAS transfer rate
3.0 Gb/s SASDrive types supported
512 MB (approximately 64 MB is used by the onboard processor)Cache size
Table 26 Smart Array P711m controller specifications
Type I, 4-port, PCIe mezzanine boardCard type
10.1 cm x 11.4 cm x 2 cm (4 in x 4.5 in x 0.8 in)Dimensions (excluding bracket)
Approximately 14 WMaximum power required
1 to 5 C (50º to 13 F)Operating temperature range
-30º to 60º C (-22º to 140º F)Storage/Shipping temperature range
10% to 90% (Storage/Shipping 5% to 90%)Operating relative humidity (noncondensing)
0, 1, 5, 6 (ADG), 5+0, 6+0RAID levels supported
119

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP Smart Array HP-UX 11i v2 and is the answer not in the manual?

HP Smart Array HP-UX 11i v2 Specifications

General IconGeneral
BrandHP
ModelSmart Array HP-UX 11i v2
CategoryServer
LanguageEnglish