Example 6 Typical sautil <device_file> command output
# sautil /dev/ciss3
******************************************************************************
**** ****
**** S A U T I L S u p p o r t U t i l i t y ****
**** ****
**** for the HP SmartArray RAID Controller Family ****
**** ****
**** version A.02.13 ****
**** ****
**** (C) Copyright 2003-2007 Hewlett-Packard Development Company, L.P. ****
******************************************************************************
---- DRIVER INFORMATION ------------------------------------------------------
Driver State........................ READY
---- CONTROLLER INFORMATION --------------------------------------------------
Controller Product Number........... P800
Controller Product Name............. HP PCIe SmartArray P800
Hardware Path....................... 0/6/0/0/0/0/1/0/0/0
Serial Number....................... P98690D9SU40R7
Device File......................... /dev/ciss3
Hardware Revision................... 'D'
Boot Block Revision................. 0.02
Firmware Revision (running)......... 4.10
Firmware Revision (in ROM).......... 4.10
Firmware Revision (inactive)........ 5.01
# of Logical Drives................. 10
# of Physical Disks Configured...... 54
# of Physical Disks Detected........ 58
Logical Drive Rebuild Priority...... 118 (high)
Array Capacity Expansion Priority... 64 (medium)
Auto-Fail Missing Disks at Boot..... enabled
SCSI Transfer Detection Mode........ Auto Detect
---- ARRAY ACCELERATOR (CACHE) INFORMATION -----------------------------------
Array Accelerator Board Present?.... yes
Cache Configuration Status.......... cache enabled
Cache Ratio......................... 50% Read / 50% Write
Total Cache Size (MB)............... 456
Read Cache........................ 228
Write Cache....................... 228
Transfer Buffer................... 000
Battery Pack Count.................. 2
Battery Status (pack #1)............ ok
Battery Status (pack #2)............ ok
---- LOGICAL DRIVE SUMMARY ---------------------------------------------------
# RAID Size Status
0 0 751610 MB OK
1 0 10239 MB OK
2 0 10239 MB OK
3 0 3072 MB OK
4 0 209925 MB OK
---- SAS/SATA DEVICE SUMMARY -------------------------------------------------
Location Ct Enc Bay WWID Type Capacity Status
internal 3I 1 4 0x5000c5000148e709 DISK 73.4 GB OK