Name Dev-id Status
----------------------- ---------------------- --------
Enclosure CZ3320E200 DEGRADED
Drawer 1 50014380308ADB00 DEGRADED
Drawer 2 50014380308ADB80 OK
PowerSupplies powerSupplies-1–2 OK
# hardware show status 50014380308ABE00
Name Dev-id Status
----------------------- ---------------------- --------
Drawer 1 50014380308ABE00 DEGRADED
Disk 5000C50059001B57 5000C50059001B57 OK
Disk 5000C50059065D1F 5000C50059065D1F OK
Disk 5000C500590686F7 5000C500590686F7 OK
- Drive_Missing_b10000d9 MISSING
Disk 5000C50059067767 5000C50059067767 OK
Disk 5000C50059001F3B 5000C50059001F3B OK
Disk 5000C5005906620F 5000C5005906620F OK
Disk 5000C5005907D57B 5000C5005907D57B OK
Disk 5000C5005906811B 5000C5005906811B OK
Disk 5000C5005906790B 5000C5005906790B OK
Disk 5000C5005906ACC7 5000C5005906ACC7 OK
Disk 5000C5005906A0E7 5000C5005906A0E7 OK
Disk 5000C500590822FB 5000C500590822FB OK
Fans fans-1-1 OK
TemperatureSensors tempsensors-1-1 OK
IOModule IOModule-1-1 OK
3. When you reach the faulty component, use the following command to display details and
look at the diagnostic message for more information.;
hardware show status <Dev-id> details
For example:
# hardware show status 50014380254FAD32 details
Name
----------------------------------------------
-
Dev-id = 50014380254FAD32
Status = DEGRADED
message = -
type = driveEnclosure
model = ServBP 4
serialNumber = -
firmwareVersion = -
location = -
Disk 5000C50055C1BB0B
Dev-id = 5000C50055C1BB0B
Status = OK
message = -
type = drive
model = MM1000FBFVR
serialNumber = 9XG3601K00009316ZLN0
firmwareVersion = HPD8
location = Port: 1I Box: 2 Bay: 1
volumeName = LUN 1
capacity = 1.00 TB
-
Dev-id = Drive_Missing_b1000103
14 Identifying problems