Controller node LEDs and ports
Figure 49: Controller node LEDs and ports, controller node enclosure rear view
1. Fault LED
2. Status LED
3. UID/Service LED
4. 10 GbE SFP port (RCIP) - optical SFP/connector
5. Link activity LED
6. Speed LED
7. 1 GbE MGMT port (management) - standard CAT-5/RJ-45 connector
8. Link activity LED - Activity/Link
9. Speed LED - Speed
10. Service port (console)
Table 14: Controller node LEDs and ports, controller node enclosure rear view
Callout LED Status State
1
Controller node:
Fault LED
Green solid Booting; not a cluster member
2
Controller node:
Status LED
Green flashing (1
blink/sec)
Normal operation
Amber solid Fault with the controller node or component
3
Controller node:
UID/Service LED
Blue solid Locate active and/or shutdown (halted); not a cluster
member; safe to remove
Blue flashing Locate active; do not remove component
Table Continued