Maximum wet bulb
temperature
Long-term
storage
(operating)
824° F (28° C)
Short-term
storage
(nonoperating)
1016° F (387° C)
Altitude: Maximum
allowable altitude change
rate is 457 m/min (1500
ft/min).
Operating
3048 m (10000 ft) This value might be
limited by the type and number of options
installed.
Nonoperating
9144 m (30000 ft)
Input power: Input
Power and Maximum
Heat specifications are
maximum values and
apply to worst-case
conditions at full rated
supply load. The power/
heat dissipation for your
installation will vary
depending on the
equipment configuration.
Input voltage
100 VAC to 240 VAC (Common-slot Power
Supply)
Input
frequency
50 Hz to 60 Hz (Common-slot Power
Supply)
Rated input
current
120V power source: 6A
240V power source: 3A
Input power
403W (maximum)
Acoustic noise levels
Listed are the declared A-Weighted sound power levels (LWAd) and declared average bystander position A-Weighted
sound pressure levels (LpAm) when the product is operating in a 23° C ambient environment. Noise emissions were
measured in accordance with ISO 7779 (ECMA 74) and declared in accordance with ISO 9296 (ECMA 109). The listed
sound levels apply to standard shipping configurations. Additional options may result in increased sound levels.
Idle Acoustic Noise (sound power)
LWAd= 70 B
Idle Acoustic Noise (sound pressure) LpAm - 53 dBA
Operating Acoustic Noise (sound power) LWAd= 70 B
Operating Acoustic Noise (sound pressure) LpAm - 53 dBA
Cables
These disk enclosures use cables with mini-SAS connectors for connections to the host and to additional cascaded disk
enclosures. Use supported SAS cables with mini-SAS connectors. A variety of SAS cables and cable lengths are supported
for use with this disk enclosure. For more information, see the HPE D3000 Enclosures QuickSpecs on the Accessing
QuickSpecs website.
Reference
38