SpecificationSpecification ValueValue
Input requirementsInput requirements —
Rated input voltage 200 VAC to 240 VAC
240 VDC for China only
Rated input frequency 50 Hz to 60 Hz
Rated input current 8.7 A at 200 VAC
7.5 A at 230 VAC
Maximum rated input power 1734 W at 200 VAC
1727 W at 230 VAC
BTUs per hour 5918 at 200 VAC
5891 at 230 VAC
Power supply outputPower supply output —
Rated steady-state power 1600 W at 200 VAC to 240 VAC input
1600 W at 240 VDC input
Maximum peak power 2200 W for 1 ms (turbo mode) at 200 VAC to 240 VAC input
Hot-plug power supply calculationsHot-plug power supply calculations
For hot-plug power supply specifications and calculators to determine electrical and heat loading for the server, see the Hewlett Packard
Enterprise Power Advisor website (https://www.hpe.com/info/poweradvisor/onlinehttps://www.hpe.com/info/poweradvisor/online).