4. Determine the status of the drive from the drive LED definitions .
5. If removed, install the front bezel .
6. Configure the controller .
ResultsResults
The installation is complete.
Energy pack optionsEnergy pack options
If there is an unplanned server power outage, the flash-backed write cache (FBWC) feature of HPE storage controllers requires a centralized
backup power source to back up the write cache data in a flash device. This server supports the following power options—collectively
known as energy pack:
HPE Smart Storage Battery
HPE Smart Storage Hybrid Capacitor
One energy pack supports multiple devices. After it is installed, the status of the energy pack appears in HPE iLO. For more information, see
the iLO user guide:
https://www.hpe.com/support/ilo6https://www.hpe.com/support/ilo6
SubtopicsSubtopics
Minimum firmware versionsMinimum firmware versions
HPE Smart Storage BatteryHPE Smart Storage Battery
HPE Smart Storage Hybrid CapacitorHPE Smart Storage Hybrid Capacitor
Installing a smart storage battery/capacitorInstalling a smart storage battery/capacitor
Minimum firmware versionsMinimum firmware versions
ProductProduct Minimum firmware versionMinimum firmware version
Server system ROM 1.20
HPE MR type-o and type-p Gen11 controllers 52.22.3-4650
HPE SR900 series type-p Gen11 controllers 03.01.14.062