Installing the Systems Insight DisplayInstalling the Systems Insight Display
Installing a rear serial port interfaceInstalling a rear serial port interface
Installing the Systems Insight DisplayInstalling the Systems Insight Display
PrerequisitesPrerequisites
Before you perform this procedure, make sure that you have the following items available:
The components included with the hardware option kit
T-10 Torx screwdriver
About this taskAbout this task
The Systems Insight Display is only supported on SFF models.
ProcedureProcedure
1. Power down the server .
2. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
3. Do one of the following:
Extend the server from the rack .
Remove the server from the rack .
4. Remove the access panel .
5. Do one of the following:
Remove the air baffle .
If installed, remove the midplane drive cage .
6. Remove the fan cage.
7. Using a T-10 driver, remove the power switch module blank. Retain the T-10 screw.
HPE ProLiant DL380 Gen11 Server User Guide 80