EasyManua.ls Logo

HPE ProLiant MicroServer Gen11 - Page 119

HPE ProLiant MicroServer Gen11
123 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ToTo UseUse
Provision, manage, and monitor clusters. HPE Performance Cluster Manager
https://www.hpe.com/support/hpcm_manualshttps://www.hpe.com/support/hpcm_manuals
Optimize your applications. HPE Performance Analysis Tools
https://www.hpe.com/info/perftoolshttps://www.hpe.com/info/perftools
Optimize software library for low latency and high bandwidth, both
on-node and off-node, for point-to-point and collective
communications.
HPE Cray Programming Environment User Guide
https://www.hpe.com/info/cray-pe-user-guideshttps://www.hpe.com/info/cray-pe-user-guides
SpecificationsSpecifications
SubtopicsSubtopics
Environmental specificationsEnvironmental specifications
Mechanical specificationMechanical specification
AC power adapter specificationsAC power adapter specifications
Environmental specificationsEnvironmental specifications
SpecificationsSpecifications ValueValue
Temperature range*Temperature range*
Operating 10°C to 35°C (50°F to 95°F)
Nonoperating -30°C to 60°C (-22°F to 140°F)
Relative humidity (noncondensing)Relative humidity (noncondensing)
Operating 8% to 90%
28°C (82.4°F) maximum wet bulb temperature, noncondensing
Nonoperating 5% to 95%
38.7°C (101.7°F) maximum wet bulb temperature, noncondensing
AltitudeAltitude
Operating 3050 m (10,000 ft)
This value may be limited by the type and number of options installed. Maximum allowable
altitude change rate is 457 m/min (1,500 ft/min).
Nonoperating 9144 m (30,000 ft)
Maximum allowable altitude change rate is 457 m/min (1,500 ft/min).
Standard operating supportStandard operating support
10° to 35°C (50° to 95°F) at sea level with an altitude derating of 1.0°C per every 305 m (1.8°F per every 1,000 ft) above sea level to a
maximum of 3,050 m (10,000 ft), no direct sustained sunlight. Maximum rate of change is 20°C/hr (36°F/hr). The upper limit and rate of
change may be limited by the type and number of options installed.
HPE ProLiant MicroServer Gen11 Maintenance and Service Guide 119