Item LED Status Definition
1 Locate Solid blue The drive is being identified by a host application.
Flashing blue The drive carrier firmware is being updated or requires an update.
2 Activity
ring
Rotating green Drive activity
Off No drive activity
3 Drive
status
Solid green The drive is a member of one or more logical drives.
Flashing green
The drive is doing one of the following:
Rebuilding
Performing a RAID migration
Performing a stripe size migration
Performing a capacity expansion
Performing a logical drive extension
Erasing
Flashing amber/
green
The drive is a member of one or more logical drives and predicts the
drive will fail.
Flashing amber The drive is not configured and predicts the drive will fail.
Solid amber The drive has failed.
Off The drive is not configured by a RAID controller.
4 Do not
remove
Solid white Do not remove the drive. The drive must be ejected from the PCIe bus
prior to removal.
Flashing white The drive ejection request is pending.
Off The drive has been ejected.
5 Power Solid green Do not remove the drive. The drive must be ejected from the PCIe bus
prior to removal.
Flashing green The drive ejection request is pending.
Off The drive has been ejected.
Component and LED identification 79