Questions and Answers

  • T
    Thomas AdamsSep 7, 2025
    What to do if hpmont HD5L-4T7P5 displays E0013 error?
    • J
      Jo MortonSep 7, 2025
      If the hpmont Controller displays error E0013, which indicates soft start contactor failed, replace the contactor.
  • M
    Meagan ThompsonAug 25, 2025
    What causes E0001 error on hpmont HD5L-4T7P5 and how to fix it?
    • J
      John DavisAug 25, 2025
      The E0001 error on your hpmont Controller means Acc overcurrent. To resolve this, ensure that the HD5L and motor are properly connected, set the correct motor parameters, select a controller with a higher rating, and set proper Acc time and Dec time.
  • A
    austinamyAug 25, 2025
    What to do if hpmont Controller displays E0017 error?
    • K
      Katherine RobertsAug 26, 2025
      If the hpmont Controller displays error E0017, which indicates a controller overload, you can adjust the Acc time, adjust the V/f curve or torque boost, check the mains supply voltage, or use a controller with proper power rating.
  • H
    Henry DavisSep 16, 2025
    Why did the soft start fail on my hpmont HD5L-4T7P5?
    • A
      Angel JonesSep 16, 2025
      If the hpmont Controller indicates a 'Soft start failed' error, it could be due to a contactor fault or a fault in the control circuit. Replace the contactor.
  • D
    David Nguyen MDSep 23, 2025
    What causes Braking unit fault in hpmont HD5L-4T7P5?
    • T
      Thomas ShahSep 23, 2025
      If the hpmont Controller reports a Braking unit fault, it indicates a circuit fault within the braking unit. Please seek technical support.
  • M
    Mrs. Brenda HernandezSep 12, 2025
    Why is there excessive speed deviation in hpmont HD5L-4T7P5?
    • D
      dbowmanSep 12, 2025
      If the hpmont Controller indicates excessive speed deviation, the possible causes are: a brake or contactor fault, PG pulse number fault, improper settings of F05.19 and F05.20, inadequate controller torque, or incorrect speed-loop PI parameter settings. To address this, consider the following: 1. Change the contactor 2. Set proper PG P/R 3. Correct the setting of F05.19 and F05.20 4. Select bigger capacity controller 5. Correctly set speed-loop PI parameter
  • M
    Mario FosterSep 2, 2025
    What to do if hpmont HD5L-4T7P5 Controller displays E0024 error?
    • T
      tammyjenningsSep 3, 2025
      If the hpmont Controller displays error E0024, which indicates a fault of external equipment, check external equipment.
  • J
    James StoutSep 3, 2025
    What to do if hpmont Controller displays E0028 error?
    • J
      Jessica FordSep 3, 2025
      If the hpmont Controller displays error E0028, which indicates SCI communication timeout, check the connection.
  • M
    Michelle ArcherSep 23, 2025
    What does Controlboard EEPROM faulty mean on hpmont HD5L-4T7P5 Controller?
    • K
      Kayla SmithSep 23, 2025
      If the hpmont Controller displays 'Controlboard EEPROM faulty', it means there is a memory circuit fault of control board EEPROM. Please contact the supplier for repairing.
  • W
    William SimmonsAug 29, 2025
    Why hpmont HD5L-4T7P5 shows E0018 error?
    • J
      Jeffrey TownsendAug 29, 2025
      The E0018 error on the hpmont Controller indicates excessive speed deviation. To fix it, change the contactor, set proper PG P/R, correct the setting of F05.19 - F05.20, select bigger capacity, and correctly set speed-loop PI parameter.

Summary

Safety Information and Precautions

Installation Limitation

Details restrictions on output side connections, voltage, and input phase usage.

Product Information

Specifications

Lists detailed electrical, performance, characteristic, and protection specifications.

Ratings

Provides a table of models, power ratings, input/output currents, and motor power.

Mechanical Installation

Installation Precautions

Outlines essential safety precautions before and during controller installation.

Requirement for the Installation Site

Specifies environmental and spatial requirements for controller installation.

Electrical Installation

Wiring Precautions

Lists critical safety precautions and guidelines for electrical wiring.

Main Circuit Terminals and Wiring

Covers terminal descriptions and wiring practices for the main power circuit.

Control Terminals and Wire Connection

Explains wiring precautions and general connections for the control circuit.

EMC Requirements and Interference Countermeasures

Provides guidelines for installation to meet EMC standards and reduce interference.

Operation Instructions

Operation Mode

Defines the four modes for receiving run commands and setting speed.

Controller Running Mode

Explains the five available running modes for the controller.

Panel Operation Examples

Provides step-by-step examples for setting parameters and managing user passwords.

Initial Power On

Guides the user through the initial power-on and controller initialization process.

Function Introduction

Elevator Application Guidance

Basic Debug Procedures

Outlines basic steps for system analysis, wiring, and parameter setup.

Troubleshooting

Fault alarm description and counter-measures

Provides a table listing fault codes, possible causes, and countermeasures.

Parameters

Group F00 Basic Parameters

Lists basic parameters with their attributes, default values, and ranges.

Group F01 Protection of Parameters

Lists parameters for parameter protection with their attributes and default values.

Group F02 Start & Stop Parameters

Lists start/stop parameters with their attributes and default values.

Group F03 Acceleration;Deceleration Parameters

Lists acceleration/deceleration parameters with their attributes and default values.

Group F05 Speed Parameters

Lists speed parameters with their attributes and default values.

Group F07 Asynchronous Motor Parameters

Lists asynchronous motor parameters with their attributes and default values.

Group F08 Motor Vector Control Speed-loop Parameters

Lists speed-loop parameters for vector control with attributes and default values.

Group F10 Synchronous Motor Parameters

Lists synchronous motor parameters with their attributes and default values.

Group F11 PG Parameters

Lists PG (encoder) parameters with their attributes and default values.

Group F12 Digital I;O Terminal Parameters

Lists digital I/O terminal parameters with their attributes and default values.

Group F13 Analogue I;O Terminal Parameters

Lists analogue I/O terminal parameters with their attributes and default values.

Group F17 Fault Protect Parameters

Lists fault protection parameters with their attributes and default values.