What to do if hpmont HD5L-4T011 displays E0013 error?
- KKim WilsonSep 7, 2025
If the hpmont Controller displays error E0013, which indicates soft start contactor failed, replace the contactor.
What to do if hpmont HD5L-4T011 displays E0013 error?
If the hpmont Controller displays error E0013, which indicates soft start contactor failed, replace the contactor.
What causes E0001 error on hpmont Controller and how to fix it?
The E0001 error on your hpmont Controller means Acc overcurrent. To resolve this, ensure that the HD5L and motor are properly connected, set the correct motor parameters, select a controller with a higher rating, and set proper Acc time and Dec time.
What to do if hpmont Controller displays E0017 error?
If the hpmont Controller displays error E0017, which indicates a controller overload, you can adjust the Acc time, adjust the V/f curve or torque boost, check the mains supply voltage, or use a controller with proper power rating.
Why did the soft start fail on my hpmont Controller?
If the hpmont Controller indicates a 'Soft start failed' error, it could be due to a contactor fault or a fault in the control circuit. Replace the contactor.
What causes Braking unit fault in hpmont Controller?
If the hpmont Controller reports a Braking unit fault, it indicates a circuit fault within the braking unit. Please seek technical support.
Why is there excessive speed deviation in hpmont HD5L-4T011?
If the hpmont Controller indicates excessive speed deviation, the possible causes are: a brake or contactor fault, PG pulse number fault, improper settings of F05.19 and F05.20, inadequate controller torque, or incorrect speed-loop PI parameter settings. To address this, consider the following: 1. Change the contactor 2. Set proper PG P/R 3. Correct the setting of F05.19 and F05.20 4. Select bigger capacity controller 5. Correctly set speed-loop PI parameter
What to do if hpmont HD5L-4T011 displays E0024 error?
If the hpmont Controller displays error E0024, which indicates a fault of external equipment, check external equipment.
What to do if hpmont Controller displays E0028 error?
If the hpmont Controller displays error E0028, which indicates SCI communication timeout, check the connection.
What does Controlboard EEPROM faulty mean on hpmont HD5L-4T011?
If the hpmont Controller displays 'Controlboard EEPROM faulty', it means there is a memory circuit fault of control board EEPROM. Please contact the supplier for repairing.
Why hpmont HD5L-4T011 Controller shows E0018 error?
The E0018 error on the hpmont Controller indicates excessive speed deviation. To fix it, change the contactor, set proper PG P/R, correct the setting of F05.19 - F05.20, select bigger capacity, and correctly set speed-loop PI parameter.
| Brand | hpmont |
|---|---|
| Model | HD5L-4T011 |
| Category | Controller |
| Language | English |
Provides guidelines for installing the controller to meet electromagnetic compatibility standards.
Introduces parameters for motor type, control mode, speed, frequency, and traction machine settings.
Covers fundamental parameters like motor type, control mode, rated speed, and operating mode.
Covers essential parameters for asynchronous motors, including rated power, voltage, current, and auto-tuning.
Covers parameters specific to synchronous motors, including type, voltage, current, and auto-tuning.
Details parameters for motor overheat, input/output phase loss, and motor overload protection.
Provides a step-by-step guide for system analysis, wiring, and parameter setup for elevator applications.
Explains the procedures for auto-tuning motors (asynchronous and synchronous) for optimal performance.
Explains how to apply the controller in terminal MS (multi-speed) run mode for elevator control.
Explains how to apply the controller in terminal analogue run mode for elevator control.
Describes the application of battery-driven run mode for emergency elevator operation during power outages.
Lists common fault codes, possible causes, and corresponding counter-measures for troubleshooting.
Covers fundamental parameters like motor type, control mode, rated speed, and operating mode.
Covers essential parameters for asynchronous motors, including rated power, voltage, current, and auto-tuning.
Details parameters for motor overheat, input/output phase loss, and motor overload protection.