Table of Contents

Questions and Answers

  • A
    Amanda FosterSep 7, 2025
    What to do if hpmont HD5L-4T011 displays E0013 error?
    • K
      Kim WilsonSep 7, 2025
      If the hpmont Controller displays error E0013, which indicates soft start contactor failed, replace the contactor.
  • J
    Jennifer DuncanAug 25, 2025
    What causes E0001 error on hpmont Controller and how to fix it?
    • R
      Rhonda KelleyAug 25, 2025
      The E0001 error on your hpmont Controller means Acc overcurrent. To resolve this, ensure that the HD5L and motor are properly connected, set the correct motor parameters, select a controller with a higher rating, and set proper Acc time and Dec time.
  • M
    Miranda GarciaAug 25, 2025
    What to do if hpmont Controller displays E0017 error?
    • T
      Tammy GuerreroAug 26, 2025
      If the hpmont Controller displays error E0017, which indicates a controller overload, you can adjust the Acc time, adjust the V/f curve or torque boost, check the mains supply voltage, or use a controller with proper power rating.
  • A
    Anthony FitzgeraldSep 16, 2025
    Why did the soft start fail on my hpmont Controller?
    • H
      Hannah CarterSep 16, 2025
      If the hpmont Controller indicates a 'Soft start failed' error, it could be due to a contactor fault or a fault in the control circuit. Replace the contactor.
  • M
    Matthew NelsonSep 23, 2025
    What causes Braking unit fault in hpmont Controller?
    • M
      Monica HunterSep 23, 2025
      If the hpmont Controller reports a Braking unit fault, it indicates a circuit fault within the braking unit. Please seek technical support.
  • K
    Kaitlyn HoweSep 12, 2025
    Why is there excessive speed deviation in hpmont HD5L-4T011?
    • B
      barajassamanthaSep 12, 2025
      If the hpmont Controller indicates excessive speed deviation, the possible causes are: a brake or contactor fault, PG pulse number fault, improper settings of F05.19 and F05.20, inadequate controller torque, or incorrect speed-loop PI parameter settings. To address this, consider the following: 1. Change the contactor 2. Set proper PG P/R 3. Correct the setting of F05.19 and F05.20 4. Select bigger capacity controller 5. Correctly set speed-loop PI parameter
  • C
    Curtis BenderSep 2, 2025
    What to do if hpmont HD5L-4T011 displays E0024 error?
    • M
      mbrownSep 2, 2025
      If the hpmont Controller displays error E0024, which indicates a fault of external equipment, check external equipment.
  • L
    Lindsay ThompsonSep 3, 2025
    What to do if hpmont Controller displays E0028 error?
    • H
      Haley ConradSep 3, 2025
      If the hpmont Controller displays error E0028, which indicates SCI communication timeout, check the connection.
  • B
    Bradley WellsSep 23, 2025
    What does Controlboard EEPROM faulty mean on hpmont HD5L-4T011?
    • P
      pdanielsSep 23, 2025
      If the hpmont Controller displays 'Controlboard EEPROM faulty', it means there is a memory circuit fault of control board EEPROM. Please contact the supplier for repairing.
  • T
    Tracy FarleyAug 29, 2025
    Why hpmont HD5L-4T011 Controller shows E0018 error?
    • K
      Keith HillAug 29, 2025
      The E0018 error on the hpmont Controller indicates excessive speed deviation. To fix it, change the contactor, set proper PG P/R, correct the setting of F05.19 - F05.20, select bigger capacity, and correctly set speed-loop PI parameter.

Summary

Chapter 3 Mechanical Installation

Chapter 1 Safety Information and Precautions

Chapter 2 Product Information

Chapter 4 Electrical Installation

4.7 Meet EMC Requirement of Installation

Provides guidelines for installing the controller to meet electromagnetic compatibility standards.

Chapter 5 Operation Instructions

Chapter 6 Function Introduction

6.2 Group F: General Function Parameters

Introduces parameters for motor type, control mode, speed, frequency, and traction machine settings.

6.2.1 Group F00 Basic Parameters

Covers fundamental parameters like motor type, control mode, rated speed, and operating mode.

6.2.8 Group F07 Asynchronous Motor Parameters

Covers essential parameters for asynchronous motors, including rated power, voltage, current, and auto-tuning.

6.2.11 Group F10 Synchronous Motor Parameters

Covers parameters specific to synchronous motors, including type, voltage, current, and auto-tuning.

6.2.18 Group F17 Fault Protect Parameters

Details parameters for motor overheat, input/output phase loss, and motor overload protection.

Chapter 7 Elevator Application Guidance

7.1 Basic Debug Procedures

Provides a step-by-step guide for system analysis, wiring, and parameter setup for elevator applications.

7.1.3 Motor Parameter Auto-tuning

Explains the procedures for auto-tuning motors (asynchronous and synchronous) for optimal performance.

7.2 Terminal MS Run Mode Application

Explains how to apply the controller in terminal MS (multi-speed) run mode for elevator control.

7.3 Terminal Analogue Run Mode Application

Explains how to apply the controller in terminal analogue run mode for elevator control.

7.4 Power-off Battery Driven Run Mode Application

Describes the application of battery-driven run mode for emergency elevator operation during power outages.

Chapter 8 Troubleshooting

Fault alarm descriptions and counter-measures

Lists common fault codes, possible causes, and corresponding counter-measures for troubleshooting.

Chapter 9 Maintenance

Appendix A Parameters

Group F00 Basic Parameters

Covers fundamental parameters like motor type, control mode, rated speed, and operating mode.

Group F07 Asynchronous Motor Parameters

Covers essential parameters for asynchronous motors, including rated power, voltage, current, and auto-tuning.

Group F17 Fault Protect Parameters

Details parameters for motor overheat, input/output phase loss, and motor overload protection.

Appendix B Communication Protocol

hpmont HD5L-4T011 Specifications

General IconGeneral
Brandhpmont
ModelHD5L-4T011
CategoryController
LanguageEnglish

Related product manuals