What causes Read / Write fault of control board EEPROM in hpmont HD3L-4T3P7?
- Jjessica62Sep 23, 2025
A read/write fault of the control board EEPROM in the hpmont Controller signifies a memory circuit fault of the control board EEPROM.

What causes Read / Write fault of control board EEPROM in hpmont HD3L-4T3P7?
A read/write fault of the control board EEPROM in the hpmont Controller signifies a memory circuit fault of the control board EEPROM.
What to do if hpmont HD3L-4T3P7 shows 'Acc overcurrent'?
If the hpmont Controller displays an 'Acc overcurrent' error, it could be due to an improper connection between the controller and motor, incorrect motor parameters, an undersized controller, or a too-short Acc/Dec time. Ensure the controller and motor are properly connected, verify the motor parameters, select a controller with a higher rating if necessary, and adjust the Acc/Dec time.
What causes hpmont Controller overload and how to fix it?
Controller overload in your hpmont device can occur if the Acc time is too short, the V/f curve or torque boost settings are incorrect, the mains supply voltage is too low, or the motor load is too high. Try adjusting the Acc time and V/f curve or torque boost settings. Also, check the mains supply voltage and consider using a controller with a proper power rating.
Why does hpmont Controller show 'Motor overload'?
The hpmont Controller may indicate a motor overload because of an improper V/f curve setting, low mains supply voltage, an incorrectly set motor overload protection factor, or a locked-rotor/overloaded motor. Adjust the V/f curve, check the power input, properly set the overload protection factor of the motor, and inspect the load and mechanical transmission devices.
What to do if hpmont HD3L-4T3P7 shows 'Acc over voltage'?
If the hpmont Controller is showing an 'Acc over voltage' error, the input voltage might be too high, the deceleration time might be too short, or the wiring is improper. Check the power input, set a proper value for Dec time, and verify the wiring.
What to do if hpmont HD3L-4T3P7 shows 'Fault of external equipment'?
If the hpmont Controller indicates a 'Fault of external equipment', the fault terminal of external equipment operates. Check external equipment.
What causes parameter auto-tuning fault on hpmont HD3L-4T3P7 Controller?
A parameter auto-tuning fault on the hpmont Controller indicates that the parameter auto-tuning has timed out. Check the motor connection and input correct nameplates parameters.
What causes soft start contactor failed in hpmont Controller?
A soft start contactor failure in the hpmont Controller can result from a contactor fault or a control circuit fault. Replace the contactor.
What causes motor overheat in hpmont HD3L-4T3P7 Controller?
Motor overheat with the hpmont Controller can be due to the motor overheating, incorrect connection of the motor overheat terminal, or incorrect motor parameter settings. Reduce the load, increase the Acc / Dec time, repair or replace the motor, detect whether the overheat detection input signal is correct and set the motor parameter according to the nameplate.
How to fix faulty setting of parameters on hpmont HD3L-4T3P7 Controller?
Faulty parameter settings on the hpmont Controller can result from a significant difference in power rating between the motor and controller, or from incorrect motor parameter settings. Select a controller with a suitable power rating and set the correct value of motor parameters.
| Brand | hpmont |
|---|---|
| Model | HD3L-4T3P7 |
| Category | Controller |
| Language | English |
Provides an overview of the user manual and its purpose for the HD3L series elevator controller.
Details critical safety information, definitions of danger/warning, and general precautions for handling HD3L.
Covers precautions, site requirements, installation direction, space, dimensions, and component handling for mechanical installation.
Explains EMC requirements, correct installation, wiring specifications, grounding, and interference reduction measures.
Introduces the HD3L series, its model, nameplate information, rated values, technical data, and physical parts.
Describes controller operation modes, status indicators, keypad functions, display statuses, and basic operation examples.
Details various function groups and parameters, including display, general, speed, protection, and communication settings.
Guides through basic commissioning, motor auto-tuning, inspection running, and specific application modes for elevators.
Provides a guide to identifying and resolving common faults, error codes, and their corresponding counter-measures.
Outlines daily, periodical, and specific maintenance tasks, along with guidance on replacing common wear parts.
Lists available accessories like keypads and cables, reactor/resistor selections, and provides a comprehensive parameter appendix.
Contains a detailed reference list of all controller parameters, their settings, defaults, and attributes.