Questions and Answers

  • B
    Brian WestSep 7, 2025
    What to do if hpmont HD5L-4T3P7 displays E0013 error?
    • D
      David SullivanSep 7, 2025
      If the hpmont Controller displays error E0013, which indicates soft start contactor failed, replace the contactor.
  • D
    Dennis LongAug 25, 2025
    What causes E0001 error on hpmont Controller and how to fix it?
    • M
      milesmarkAug 25, 2025
      The E0001 error on your hpmont Controller means Acc overcurrent. To resolve this, ensure that the HD5L and motor are properly connected, set the correct motor parameters, select a controller with a higher rating, and set proper Acc time and Dec time.
  • Z
    zjeffersonAug 25, 2025
    What to do if hpmont HD5L-4T3P7 Controller displays E0017 error?
    • S
      Steven DanielsAug 26, 2025
      If the hpmont Controller displays error E0017, which indicates a controller overload, you can adjust the Acc time, adjust the V/f curve or torque boost, check the mains supply voltage, or use a controller with proper power rating.
  • D
    David McdonaldSep 16, 2025
    Why did the soft start fail on my hpmont Controller?
    • S
      Susan PrestonSep 16, 2025
      If the hpmont Controller indicates a 'Soft start failed' error, it could be due to a contactor fault or a fault in the control circuit. Replace the contactor.
  • C
    Cole DavisSep 23, 2025
    What causes Braking unit fault in hpmont Controller?
    • V
      Virginia SimpsonSep 23, 2025
      If the hpmont Controller reports a Braking unit fault, it indicates a circuit fault within the braking unit. Please seek technical support.
  • T
    Terry RyanSep 12, 2025
    Why is there excessive speed deviation in hpmont Controller?
    • M
      Margaret BoyerSep 12, 2025
      If the hpmont Controller indicates excessive speed deviation, the possible causes are: a brake or contactor fault, PG pulse number fault, improper settings of F05.19 and F05.20, inadequate controller torque, or incorrect speed-loop PI parameter settings. To address this, consider the following: 1. Change the contactor 2. Set proper PG P/R 3. Correct the setting of F05.19 and F05.20 4. Select bigger capacity controller 5. Correctly set speed-loop PI parameter
  • T
    Theresa RodgersSep 2, 2025
    What to do if hpmont HD5L-4T3P7 Controller displays E0024 error?
    • H
      harmonjoseSep 3, 2025
      If the hpmont Controller displays error E0024, which indicates a fault of external equipment, check external equipment.
  • G
    Gwendolyn WashingtonSep 3, 2025
    What to do if hpmont HD5L-4T3P7 displays E0028 error?
    • T
      Tanner BradshawSep 3, 2025
      If the hpmont Controller displays error E0028, which indicates SCI communication timeout, check the connection.
  • M
    Melissa BenjaminSep 23, 2025
    What does Controlboard EEPROM faulty mean on hpmont HD5L-4T3P7 Controller?
    • M
      Melissa DavisSep 23, 2025
      If the hpmont Controller displays 'Controlboard EEPROM faulty', it means there is a memory circuit fault of control board EEPROM. Please contact the supplier for repairing.
  • Y
    yadkinsAug 29, 2025
    Why hpmont Controller shows E0018 error?
    • J
      jasonturnerAug 29, 2025
      The E0018 error on the hpmont Controller indicates excessive speed deviation. To fix it, change the contactor, set proper PG P/R, correct the setting of F05.19 - F05.20, select bigger capacity, and correctly set speed-loop PI parameter.

Summary

Chapter 1 Safety Information and Precautions

1.3 Installation Limitation

Details restrictions on output side components, voltage, input phases, and derating.

Chapter 2 Product Information

2.3 Specifications

Lists electrical, performance, and protection specifications of the controller.

2.4 Ratings

Provides a table of model ratings for single-phase and three-phase power supply.

Chapter 3 Mechanical Installation

3.1 Installation Precautions

Lists essential safety precautions that must be followed during installation.

3.2 Requirement for the Installation Site

Specifies environmental and spatial requirements for the installation location.

Chapter 4 Electrical Installation

4.1 Wiring Precautions

Outlines critical safety rules and precautions for electrical wiring.

4.2 Selection of Main Circuit Peripheral Devices

Recommends peripheral devices for the main circuit based on model specifications.

4.3 Main Circuit Terminals and Wiring

Details the main circuit terminals and provides general wiring guidelines.

4.4 Control Terminals and Wire Connection

Discusses control circuit safety, cable management, and interference suppression.

4.6 Encoder Card

Introduces different types of encoder cards and their respective functions.

4.7 Meet EMC Requirement of Installation

Explains how to ensure Electromagnetic Compatibility (EMC) during installation.

Chapter 5 Operation Instructions

Chapter 6 Function Introduction

Chapter 7 Elevator Application Guidance

7.1.3 Motor Parameter Auto-tuning

Explains the step-by-step process for motor parameter auto-tuning.

7.4 Power-off Battery Driven Run Mode Application

Describes the battery-driven run mode for emergency situations during power outages.

Chapter 8 Troubleshooting

Table 8-1 Fault alarm description and counter-measures

Lists common fault codes, their possible reasons, and recommended countermeasures.

Appendix A Parameters

Group F17 Fault Protect Parameters

Lists fault protect parameters and their attributes.