9.5.2 Error Messages
Symbol Error Message Fault description Action
CANBUS ERROR Error on CAN bus.
Check cabling. Check
units connected to
HMI.
EMERGENCY STOP
ACTIVATED
Emergency stop
activated.
Reset emergency stop.
Check the remote
control and reconnect
radio with the
connection button. See
Radio Control Radio
Control page 47
GENERIC INVERTOR
ERROR
Generic error converter,
radio, left/right drive
motor.
Go to the HTC Support
website.
GENERIC........ ERROR
(error code)
Generic error converter,
radio, left/right drive
motor.
Go to the HTC Support
website.
HEATSINK
TEMPERATURE HIGH
Cooling flange for
frequency converter is
overheated.
Let the frequency
converter cool down.
INVERTER OVERLOAD
The converter is
overloaded.
Let the machine cool
down.
LEFT DRIVE MOTOR
VOLTAGE LOW / RIGHT
DRIVE MOTOR
VOLTAGE LOW
Low voltage left drive
motor.
Check control voltage.
Check battery voltage.
Check cabling to drive
motors. Check voltage
on relay outputs.
MOTOR NOT
CONNECTED
Break in grinding
motor/grinding motor
cabling.
Check grinding motor
cabling. Check
measure grinding
motor.
MOTOR OVERHEAT
Grinding motor is
overheated.
Let the motor cool
down.
MOTOR OVERLOAD
Grinding motor becomes
overloaded. Overload
meter up to 100%.
Let the machine cool
down.
MOTOR SHORT
CIRCUIT
Grinding motor
short-circuited.
Check grinding motor
cabling. Insulation
measure grinding
motor.