Tools and Accessories
l ESD wrist strap
l AC Power Cable
l AC terminal locking latch
Procedure
Step 1 Verify that the router is reliably grounded.
Step 2 Set the power switch to OFF.
Step 3 Wear an ESD wrist strap. Ensure that the ESD wrist strap is grounded and in a close contact
with your wrist.
Step 4 Connect the AC power cable.
1. Connect one end of the AC power cable to the power socket on the router.
2. Connect the other end of the AC power cable to an AC power outlet.
ON
OFF
~100-240V;50/60Hz;3A
+12V; 11.5A
LINK
ACT
SLOT CARD E1
AR2202-48FE
LINK
ACT
SA
LINK
ACT
AC power outlet
AC Power Cable
ON
OFF
~100-240V;50/60Hz;3A
Step 5 Connect the AC terminal locking latch.
1. Insert the AC terminal locking latch into the jack on the rear panel of the router.
2. Adjust the AC terminal locking latch to a proper position.
3. Lock the AC power cable with the AC terminal locking latch.