Pre-configuration Tasks
Before configuring a SIP AG user, complete the following tasks:
l Setting the operation mode to SIP AG
l Configuring a SIP AG interface
Data Preparation
To configure a SIP AG user, you need the following data.
No. Data
1 SIP AG user interface number, SIP AG ID for the SIP AG user, and phone number
of the SIP AG user
2 (Optional) SIP AG ID for the SIP AG user, SIP AG user in the SIP service data profile,
and phone number of the SIP AG user in the SIP service data profile
1.7.2 Setting Parameters for a SIP AG User
This section describes how to set parameters for a SIP AG user.
Applicable Environment
On the IMS, a SIP AG is directly connected to a user terminal. You need to set parameters for
users on the SIP AG so that the users can use services on the IMS.
Procedure
Step 1 Run:
system-view
The system view is displayed.
Step 2 Run:
voice
The voice view is displayed.
Step 3 Run:
sipaguser sipaguser-name
A SIP AG user is created and the SIP AG user view is displayed.
After a SIP AG user is created, set parameters for the SIP AG user, including the interface
number, SIP AG ID, and phone number.
Step 4 Run:
port interface-number
An interface number is configured for the SIP AG user.
Step 5 Run:
mgid mgid
Huawei AR1200 Series Enterprise Routers
Configuration Guide - Voice 1 SIPAG Configuration
Issue 03 (2011-09-30) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.