1.7.4 (Optional) Configuring Functions or Services in a SIP Service
Data Profile
This section describes how to configure functions or services in a SIP AG service data profile.
Applicable Environment
After a SIP AG user is configured, communication can be implemented. You can enable other
services for the SIP AG user according to user requirements.
Before configuring other services for a SIP AG user, run the conference disable command in
the SIP AG service data profile to disable the call conference service.
Procedure
Step 1 Run:
system-view
The system view is displayed.
Step 2 Run:
voice
The voice view is displayed.
Step 3 Run:
sipservicedata name
The SIP service data profile view is displayed.
Step 4 Run:
sipaguser name
A SIP AG user is created.
Step 5 Run:
telno telno-value
The phone number of the SIP AG user is configured.
Step 6 Configure the following functions or services in the SIP service data profile.
Function/Service
Command Default Setting
Authentication user
name
auth-username auth-
username
No authentication user name
configured
Authentication password auth-password auth-password No authentication password
configured
Password authentication
mode
auth-password-mode
{ password | ha1 }
Original password
authentication
Dial tone type dial-tone { normal | special |
mw }
Normal dial tone type
Huawei AR1200 Series Enterprise Routers
Configuration Guide - Voice 1 SIPAG Configuration
Issue 03 (2011-09-30) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.