Indicators on the front panel: 
Silkscreen  Color  Function 
SYS 
Green / Red / Yellow 
/Off 
Green – Normal and no alarm. 
Red – Critical alarm occurs. 
Yellow – Major or minor alarm occurs. 
Off – Out of power. 
FAN  Green / Red / Off  Green – Normal and no alarm of fan board. 
Red – Alarm occurs in fan board. 
Off – Out of power. 
West  Green / Red / Off  Green – West OSC Ethernet link is ok. 
Red – RLOS happens at west OSC. 
Off – Out of power or no SFP inserted. 
East  Green / Red / Off  Green – East OSC Ethernet link is ok. 
Red – RLOS happens at east OSC. 
Off – Out of power or no SFP inserted. 
     
Interfaces on the front panel: 
Interfaces  Connector type  Description 
CONSOLE  RJ11 
Factory debugging and maintenance 
interface. 
ETH1  RJ45 
10/100M self-adapted Ethernet interface 
for NM connection or NE cascading. 
ETH2  RJ45 
10/100M self-adapted Ethernet interface 
for NM connection or NE cascading. 
TM1  LC  Tx port of west OSC. 
RM1  LC  Rx port of west OSC. 
TM2  LC  Tx port of east OSC. 
RM2  LC  Rx port of east OSC. 
     
Switches on the front panel: 
Switches  Description 
RST  Reset button for board resetting