Loading...
Figure 5-23 Balanced three-phase grid connection
Figure 5-24 Connecting cables to the smart power sensor (balanced
three-phase grid connection)
NO TE
In cascading scenarios, the inverters are required to connect to the management
system through a Smart Dongle.
In the preceding networking, the SUN2000s are cascaded and support the grid-tied
point control function to achieve zero export.
If the SUN2000s requires the grid-tied point control function, they need to be
connected to a smart power sensor.
In the scenario of balanced three-phase grid connection, if the SUN2000s requires
the grid-tied point control function, they need to be connected to a three-phase
smart power sensor to control the total three-phase power.
Only one LG battery is supported, and the LG battery must be connected to the
inverter equipped with the Smart Dongle.
For Australia and New Zealand markets, Inverters should not be installed in
multiple phase combinations.
Copy-SUN2000-(2KTL-6KTL)-L1
User Manual 5 Electrical Connection
Issue 06 (2022-03-10) Copyright © Huawei Technologies Co., Ltd. 54