Category Description
Installation space ● Requirements for cabinet installation:
Cabinet compliant with the International
Electrotechnical Commission (IEC) 297 standard
– Cabinet width: 482.6 mm (19 in.)
– Cabinet depth ≥ 1000 mm (39.37 in.)
● Requirements for guide rail installation:
– L-shaped guide rails: apply only to Huawei
cabinets.
– Static rail kit: applies to cabinets with a distance
of 543.5 mm to 848.5 mm (21.40 in. to 33.41 in.)
between the front and rear mounting bars.
– Ball bearing rail kit: applies to cabinets with a
distance of 610 mm to 914 mm (24.02 in. to
35.98 in.) between the front and rear mounting
bars.
Weight in full
conguration
● Maximum net weight:
– Server with 8 x 2.5" drives: 17.3 kg (38.15 lb)
– Server with 4 x 3.5" drives: 18.4 kg (40.57 lb)
– Server with 10 x 2.5" drives: 17.8 kg (39.25 lb)
● Packaging materials: 5 kg (11.03 lb)
Power consumption The power consumption parameters vary with
hardware congurations (including the congurations
complying with EU ErP). Use the Intelligent
Computing Product Power Calculator to obtain
specic information.
FusionServer Pro 1288H V5 Server
User Guide 3 Product Specications