Step 3 Connect the other end of the power cable to the DC PDU in the cabinet.
The DC PDU is fastened horizontally in the rear of the cabinet. Connect the power
cable to the socket on the PDU according to the plan.
Step 4 Bundle the power cables to the cable guide using cable ties.
----End
7.2.6.9 Checking Cable Connections
Before checking cable connections, ensure that the power is cut o. Otherwise,
any incorrect connection or loose connection may cause human injury or device
damage.
Table 7-3 Cable connection checklist
Item Description
Power cable Power cables are correctly connected to the rear of the
chassis.
Network cable Network cables are connected correctly to the
management port or service ports on the rear panel of
the chassis.
Ground cable The server does not provide a separate ground port.
● In AC or HVDC environment, the power cables of AC
PSUs are grounded. Ensure that the power cables
are in good contact.
● In DC environment, the ground terminals of DC
PSUs are grounded. Ensure that the ground cables
are in good contact.
7.3 Power-On and
Power-O
FusionServer Pro 1288H V5 Server
User Guide 7 Installation and Conguration
Issue 13 (2020-06-05) Copyright © Huawei Technologies Co., Ltd. 82