NO TICE
The cleared data cannot be restored. Exercise caution when performing this
operation.
Procedure
Before performing this operation, check that:
The storage device is not in a RAID array with redundancy, and the server operating
system is running properly.
You have obtained the server No. and the slot No. and location of the storage device to
be cleared.
Step 1 You have accessed the desktop of the server where the target drive is located.
For details, see 9.3.1 Using the Remote Virtual Console.
Step 2 Open the CLI.
Step 3 Query information about drive letters.
lsscsi
Figure 9-18 Querying drive letters
Step 4 Query drive information.
fdisk -l
The drive with the * symbol in the Boot column is the system drive. As shown in Figure
9-19, sda is the system drive.
Do not directly clear system drive data. Before clearing system drive data, clear data
from other storage media.
FusionServer Pro 2288X V5 Server
User Guide 9 Common Operations
Issue 04 (2020-06-05) Copyright © Huawei Technologies Co., Ltd. 136