EasyManua.ls Logo

Huawei FusionServer Pro 2288X V5 - Page 161

Huawei FusionServer Pro 2288X V5
173 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Sensor Description Component
PCH Status PCH chip fault diagnosis
health status
Mainboard
CPU
N
UPI Link CPU UPI link fault
diagnosis health status
Mainboard or CPU
N
N
indicates the CPU
number. The value is 1 or
2.
CPU
N
Prochot CPU Prochot CPU
N
N
indicates the CPU
number. The value is 1 or
2.
CPU
N
Status CPU status CPU
N
N
indicates the CPU
number. The value is 1 or
2.
CPU
N
Memory CPU memory status DIMMs of CPU
N
N
indicates the CPU
number. The value is 1 or
2.
FAN
N
Status Fan status Fan module
N
N
indicates the fan
module number. The
value ranges from 1 to 4.
DIMM
N
DIMM status DIMM
N
N
indicates the DIMM
slot number.
RTC Battery RTC battery status. An
alarm is generated when
the voltage is lower than
1 V.
RTC battery
PCIE Status PCIe status PCIe cards
Power Button Power button pressed
state
Mainboard and power
button
Watchdog2 Watchdog Mainboard
Mngmnt Health Management subsystem
health status
Management modules
UID Button UID button status Mainboard
PwrOk Sig. Drop Voltage dip status Mainboard
PwrOn TimeOut Power-on timeout Mainboard
FusionServer Pro 2288X V5 Server
User Guide A Appendix
Issue 04 (2020-06-05) Copyright © Huawei Technologies Co., Ltd. 153

Table of Contents

Other manuals for Huawei FusionServer Pro 2288X V5