For safety concern, at least two persons are required to install a subrack. One person is to hold the subrack and
the other person to tighten the panel screws.
Place the the subrack onto the column guide rails inside the
cabinet.
Secure the subrack on the cabinet columns with panel screws.
Remove the front door and side doors of the cabinet before routing cables. For details on how to remove the
doors, see the
N63B Cabinet Installation Guide
.
1 Installing Subracks(Subracks and Single DCM Frame)
Installing Subracks and Boards
Front
OptiX OSN 6800
Subrack 4
OptiX OSN 6800
Subrack 3
Air deflector
OptiX OSN 6800
Subrack 2
OptiX OSN 6800
Subrack 1
Structural
component
Installation
holes on one
column
DCM frame 2, 3
Subrack 1 5, 6, 19, 20
Subrack 2 21, 22, 35, 36
Air deflector 37, 40
Subrack 3 46, 47, 60, 61
Subrack 4 62, 63, 76, 77
TN11PDU 79, 83
DPD63-4-8
PDU
81, 83
Cabinet
column
Panel screw
NOTE
NOTE