OptiX RTN 600
Product Description
Commercial in Confidence Page 44 of 44
Table 7-21
Environment of the OptiX RTN 600
Component
Item
IDU ODU
Operation
Compliant with ETSI
EN 300 019 class 3.2.
Compliant with ETSI EN 300 019
class 4.1.
Transportation
Compliant with ETSI EN 300 019 class 2.3.
Major
reference
standards
Storage
Compliant with ETSI EN 300 019 class 1.2.
Operation
-5°C to 50°C
-40°C to 45°C (without solar
radiation)
-40°C to 60°C (with solar radiation,
1120 W/m²)
Air
temperature
Transportation
and storage
-40°C to 70°C
-45°C to 70°C
Operation
5% to 95%
Relative
humidity
Transportation
and storage
10% to 100%
5% to 100%
Operation
700 W/m²
Solar radiation
Transportation
and storage
1120 W/m²
1120 W/m²
Operation
4000m
4500m
Altitude
Transportation
and storage
5000m
15000m
Noise
< 7.2 bel, compliant
with ETSI EN 300 753
(7)
-
Earthquake
Compliant with Bellcore GR-63-CORE ZONE 4.
Mechanical stress
Compliant with ETSI EN 300 019.

Table of Contents