Huawei Technologies Proprietary 
4-25 
  Note:  
For the T1 module, corresponding serial interface shall be created after you use the 
timeslot bundling command on the Controller T1 interface. See VRP3.4 Operation 
Manual for details.  
 
2)  T1 interface cable  
T1 interface matches 100-ohm  standard shielded cable. See the following table:  
 
Figure 4-30 T1 interface cable 
For the pinouts of T1 interface cable, see Low-End and Mid-Range Series Routers 
Cable Manual.  
You can also choose to use network connector assembly, for extending two T1 
interface cables.  
 
  Note:  
T1 interface cable and network connector assembly are optional, so you have to order 
them as needed when purchasing the AR 28-14.  
 
3)  Connecting T1 interface cable  
 
  Caution:  
z  Check the interface mark before connection to avoid cable mis-insertion and router 
damage.  
z  When the T1 interface cable is routed outdoors, you need use the special lightning 
protection unit at the input end to prevent possible damage.  
 
Step 1: Insert one end of the T1 interface cable into the E1 interface of the router.  
Step 2: Insert the other end to the peer device.  
z  If one cable is enough in length, insert the other end to the peer device.