Type Tools and Instruments
Marker Steel measuring tape Level
Hydraulic pliers Heat-shrink tubing Heat gun
Personal protective
equipment (PPE)
Insulated gloves Protective gloves
Dust mask
Safety boots
Safety goggles
-
4.3 Determining the Installation Position
Basic Requirements
The SUN2000 is protected to IP65 and can be installed indoors or outdoors.
Do not install the SUN2000 in a place where personnel are easy to come into
contact with its enclosure and heat sink, because these parts are extremely
hot during operation.
Do not install the SUN2000 near
ammable or explosive materials.
Do not install the SUN2000 at a place within children's reach.
The SUN2000 will be corroded in salt areas, and the salt corrosion may cause
re. Do not install the SUN2000 outdoors in salt areas. A salt area refers to
the region within 500 meters from the coast or prone to sea breeze. The
SUN2000-(2KTL-6KTL)-L1
User Manual 4 System Installation
Issue 10 (2023-02-13) Copyright © Huawei Technologies Co., Ltd. 26

Table of Contents

Other manuals for Huawei SUN2000-4KTL-L1

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Huawei SUN2000-4KTL-L1 and is the answer not in the manual?

Huawei SUN2000-4KTL-L1 Specifications

General IconGeneral
Max. efficiency98.4%
Max. input voltage600 V
Rated output power4000 W
Dimensions (W x H x D)365 x 365 x 156 mm
Max. apparent AC power4000 VA
Nominal AC voltage220 V / 230 V / 240 V
MPPT voltage range200-1000 V
Number of MPP trackers2
Max. short-circuit current per MPPT15 A
Operating temperature range-25°C to +60°C
Protection degreeIP65
Max. Input Power6000 W
Max. Output Power4000 W
Rated Output Voltage220 V / 230 V / 240 V
Output Frequency50 Hz / 60 Hz
Cooling MethodNatural convection
AC voltage range180 V to 280 V