Figure 7-8 Physical layout design of PV modules
----End
Scenario 2: Setting on the Solar Inverter Side (Solar Inverter Not Connected
to the Management System)
Step 1 Access the Device Commissioning screen on the FusionSolar App to set the
physical layout of Smart PV Optimizers.
1. Log in to the FusionSolar App. On the Device Commissioning screen, choose
Maintenance > Optimizer layout. The Optimizer layout screen is displayed.
2. Tap the blank area. The Identify image and Add PV modules buttons are
displayed. You can use either of the following methods to perform operations
as prompted:
Method 1: Tap Identify image and upload the physical layout template
photo to complete the optimizer layout. (The optimizers that fail to be
identied need to be manually bound.)
Method 2: Tap Add PV modules to manually add PV modules and bind
the optimizers to the PV modules.
Figure 7-9 Physical layout design of PV modules
----End
7.2 Parameters Settings
Go to the Device Commissioning screen and set SUN2000 parameters. For details
about entering the Device Commissioning screen, see B Device Commissioning.
To set more parameters, tap Settings. For details about the parameters, see the
FusionSolar App and SUN2000 App User Manual
. You can also scan the QR
code to obtain the document.
SUN2000-(2KTL-6KTL)-L1
User Manual 7 Man-Machine Interaction
Issue 10 (2023-02-13) Copyright © Huawei Technologies Co., Ltd. 73

Table of Contents

Other manuals for Huawei SUN2000-4KTL-L1

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Huawei SUN2000-4KTL-L1 and is the answer not in the manual?

Huawei SUN2000-4KTL-L1 Specifications

General IconGeneral
Max. efficiency98.4%
Max. input voltage600 V
Rated output power4000 W
Dimensions (W x H x D)365 x 365 x 156 mm
Max. apparent AC power4000 VA
Nominal AC voltage220 V / 230 V / 240 V
MPPT voltage range200-1000 V
Number of MPP trackers2
Max. short-circuit current per MPPT15 A
Operating temperature range-25°C to +60°C
Protection degreeIP65
Max. Input Power6000 W
Max. Output Power4000 W
Rated Output Voltage220 V / 230 V / 240 V
Output Frequency50 Hz / 60 Hz
Cooling MethodNatural convection
AC voltage range180 V to 280 V