EasyManua.ls Logo

Huawei SUN2000-50KTL-JPM0 - Setting Protection Parameters

Huawei SUN2000-50KTL-JPM0
113 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SUN2000-(50KTL-JPM0, 50KTL-JPM1, 63KTL-JPM0)
User Manual
7 Man-Machine Interactions
Copyright © Huawei Technologies Co., Ltd.
80
No.
Parameter
Description
Unit
Value Range
9
Reactive power
compensation
(cosφ-P) trigger
voltage
Specifies the voltage threshold for
triggering reactive power compensation
based on the cosφ-P curve.
%
[100, 110]
10
Reactive power
compensation
(cosφ-P) exit
voltage
Specifies the voltage threshold for exiting
reactive power compensation based on
the cosφ-P curve.
%
[90, 100]
7.2.2.2 Setting Protection Parameters
Procedure
Step 1 Choose Function Menu > Settings > Protection Parameters to access the settings screen.
Figure 7-6 Protection parameters (special user)
----End
Parameter List
No.
Parameter
Description
Unit
Value Range
Remarks
1
Unbalance voltage
protection
Specifies the SUN2000
protection threshold in the
case of unbalanced power
grid voltage.
%
[0.0, 50.0]
N/A

Table of Contents