Item SUN2000-75KTL-C1 SUN2000-70KTL-C1
Number of MPP trackers 6
Note a: The maximum input voltage is the upper threshold of the DC voltage. If
the input voltage exceeds the threshold, the solar inverter may be damaged.
Note b: If the input voltage is beyond the operating voltage range, the solar
inverter cannot work properly.
Output
Item SUN2000-75KTL-C1 SUN2000-70KTL-C1
Rated active power 75 kW 70 kW
Maximum apparent
power
82.5 kVA 77 kVA
Maximum active power
(cosφ = 1)
82.5 kW 77 kW
Rated output voltage 288 V/500 V, 3W+PE
Rated output current 86.7 A 80.9 A
Adapted grid frequency 50 Hz
Maximum output current 95.3 A 89 A
Power factor 0.8 leading... 0.8 lagging
Maximum total harmonic
distortion (rated power)
< 3%
Protection
Item
SUN2000-75KTL-C1 SUN2000-70KTL-C1
Input DC switch Supported
Anti-islanding protection Supported
Output overcurrent
protection
Supported
Input reverse polarity
protection
Supported
PV string fault detection Supported
DC surge protection Type II
AC surge protection Type II
SUN2000-(70KTL, 75KTL)-C1
User Manual 10 Technical Specications
Issue 09 (2020-10-12) Copyright © Huawei Technologies Co., Ltd. 107