EasyManua.ls Logo

Huawei TaiShan 200 Series - 3.4 PSU Specifications

Huawei TaiShan 200 Series
132 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Item Description
Installation
space
Requirements for cabinet installation (cabinet compliant with
the International Electrotechnical Commission (IEC) 297
standard):
Cabinet width: 482.6 mm (19 in.)
Cabinet depth: ≥ 1000 mm (39.37 in.)
Requirements for guide rail installation:
L-shaped guide rails: apply only to Huawei cabinets.
Adjustable guide rails: apply to a cabinet with a distance of
543.5 mm to 848.5 mm (21.40 in. to 33.41 in.) between the
front and rear mounting bars.
Holding rails: apply to a cabinet with a distance of 610 mm
to 914 mm (24.02 in. to 35.98 in.) between the front and rear
mounting bars.
Weight in full
conguration
Net weight:
Server with 12 x 3.5-inch front drives + 4 x 3.5-inch rear
drives + 4 x 2.5-inch rear drives: 32 kg (70.55 lb)
Server with 25 x 2.5-inch front drives + 2 x 3.5-inch rear
drives + 4 x 2.5-inch rear drives: 25 kg (55.12 lb)
Server with 8 x 2.5-inch SAS/SATA front drives + 12 x 2.5-inch
front NVMe SSDs + 4 x 2.5-inch rear drives: 24 kg (52.91 lb)
Server with 24 x 2.5-inch front drives + 4 x 2.5-inch rear
drives: 24 kg (52.91 lb)
Packaging materials: 5 kg (11.03 lb)
Power
consumption
The power consumption parameters vary according to
congurations. Use the Intelligent Computing Product Power
Calculator to obtain the specic power consumption value.
3.4 PSU
Specications
The PSUs are hot-swappable and work in 1+1 redundancy mode.
For details about supported PSUs, use the Intelligent Computing
Compatibility Checker.
The recommended current
specications for the external power circuit breaker
connected to the server are as follows:
AC power supply: 32 A
DC power supply: 63 A
A server must use PSUs of the same model.
The PSUs provide short-circuit protection. The PSUs that support dual input
live wires provide double-pole fuse.
If the input voltage ranges from 200 V to 220 V AC, the output power of the
2000 W AC platinum PSU decreases to 1800 W.
TaiShan 200 Server
User Guide (Model 2280) 3 Product Specications
Issue 04 (2020-01-16) Copyright © Huawei Technologies Co., Ltd. 38

Table of Contents