UPS2000-G- (6 kVA-20 kVA)
User Manual
Issue 18
Date 2021-07-16
HUAWEI TECHNOLOGIES CO., LTD.

Table of Contents

Other manuals for Huawei UPS2000-G-10KRTL

Questions and Answers

  • J
    John SmithSep 23, 2025
    What to do if Huawei UPS2000-G-10KRTL UPS makes abnormal noises or smells?
    • P
      phelpsstephenSep 23, 2025
      If your Huawei UPS is generating abnormal noises or smells, it indicates a fault. Immediately shut down the UPS, cut off the input power supply, and contact local Huawei technical support.
  • D
    Darren HunterAug 23, 2025
    What to do if the AC input indicator is off on my Huawei UPS2000-G-10KRTL?
    • J
      Jeffrey OwenAug 23, 2025
      If the AC input indicator is off and the UPS is running on battery despite normal mains, it could be due to the UPS mains switch being OFF. Ensure the UPS mains switch is turned ON. Alternatively, the input cable may not be properly connected; check the UPS input power cable connection.
  • R
    Rhonda RyanAug 25, 2025
    What to do if the battery indicator blinks on my Huawei UPS?
    • M
      Mark SmithAug 26, 2025
      If the battery indicator is blinking and the buzzer is buzzing, it indicates that the UPS is about to shut down due to insufficient battery reserve. To prevent data loss or damage, immediately save load data and shut down primary loads. Also, verify that the number of batteries and battery capacity are correctly set based on the actual configuration.
  • K
    knightrickyAug 26, 2025
    Why is the mains indicator off on my Huawei UPS?
    • C
      Cody BarnesAug 27, 2025
      The mains indicator might be off because the mains voltage or frequency exceeds the UPS input range. Use a multimeter to verify that the input voltage and frequency meet the specified requirements.
  • C
    Christopher SullivanAug 27, 2025
    How to fix a Huawei UPS2000-G-10KRTL when the LCD displays nothing?
    • A
      Andrea GonzalezAug 27, 2025
      If the LCD displays nothing and the system doesn't perform self-tests, first check the UPS input power cable connection to ensure the input power supply is properly connected. Also, use a voltmeter to check whether the UPS input voltage meets the required specifications, as it may be less than the lower threshold or greater than the upper threshold.
  • B
    Brian CoxSep 17, 2025
    Why is the Huawei UPS2000-G-10KRTL UPS battery indicator blinking yellow and the buzzer buzzing?
    • A
      ashley80Sep 17, 2025
      A blinking yellow battery indicator and a buzzing sound on your Huawei UPS signal insufficient battery capacity, which is causing the UPS to shut down. To address this, immediately save load data and power off any non-critical loads. This issue can also be caused by incorrect parameter settings for battery number or capacity. Connect UPS input terminals to the backup AC power supply.
  • M
    Mr. William May IISep 14, 2025
    How to fix a Huawei UPS2000-G-10KRTL when the LCD is blank and it won't self-test?
    • M
      margaret92Sep 14, 2025
      If your Huawei UPS's LCD is blank and it's not performing self-tests, there are a couple of things to check. First, ensure that the input power cable is properly connected. Also, use a multimeter to check that the UPS input voltage meets the required specifications.
  • M
    Michael HernandezSep 15, 2025
    What to do if Huawei UPS2000-G-10KRTL UPS won't start?
    • A
      Anthony WolfeSep 15, 2025
      If your Huawei UPS doesn't start when you press the power button, try pressing and holding the button for more than 5 seconds until you hear a beep. If that doesn't work, disconnect all loads and then restart the UPS.
  • T
    tcooperSep 6, 2025
    How to extend battery discharge time on Huawei UPS?
    • E
      Erica HernandezSep 6, 2025
      If the battery discharge time of your Huawei UPS is much less than the standard time, it could be due to batteries not being fully charged. Charge the batteries for more than 8 hours when the mains is normal and then test the discharge time again. If the issue persists, the battery performance may have deteriorated, and you should contact local Huawei technical support to replace the batteries.
  • B
    Brooke KellerSep 3, 2025
    What to do if the battery indicator is blinking yellow on my Huawei UPS?
    • D
      ddunnSep 3, 2025
      If the battery indicator is blinking yellow, the buzzer buzzes for 1 second and then stops for 1 second, and the UPS is shutting down due to insufficient battery capacity, immediately save load data and power off critical loads. It may also be caused by incorrect parameter settings for the battery number or capacity, so ensure these parameters are set correctly.

Summary

About This Document

Purpose

Describes the UPS models, features, operation, and maintenance.

Intended Audience

Lists the roles for whom this document is intended.

Symbol Conventions

Defines symbols used in the document for hazard communication.

Safety Information

General Safety

General safety precautions and Huawei's liability.

General Requirements

Specific general safety practices and equipment protection.

Personal Safety

Safety measures for personnel.

Personnel Requirements

Qualification and training for personnel.

Electrical Safety

Safety related to electrical aspects including grounding and power.

Installation Environment Requirements

Environmental conditions for installation.

Mechanical Safety

Safety during physical handling, including moving heavy objects.

Equipment Operating Environment

Specifies the intended use environment for the UPS.

Battery Safety

Safety precautions and requirements for handling and installing batteries.

Quick Introduction

Model Description

Details the different UPS models covered in the manual.

Working Principle

Explains how the UPS operates, including diagrams and modes.

Appearance

Describes the physical layout and connections of the UPS.

Optional Components

Lists and describes optional accessories for the UPS.

Installation

Preparations

Steps and checks required before installation.

Installation Procedure

Overall steps for installing the UPS system.

Installing a Backfeed Protection Device

Procedure for installing backfeed protection devices.

Verifying the Installation

Checks to perform after the UPS installation is complete.

Control Panel

Introduction

Overview of the UPS control panel and its functions.

Indicators

Explanation of the status indicators on the control panel.

Functional Buttons

Description of the control panel buttons and their operations.

LCD

Description of the LCD display functionality and features.

LCD Startup Screen

Details the initial screen displayed upon UPS startup.

LCD Menu Hierarchy

Visual representation of the UPS menu structure.

Status Screen

Details the different status display screens for UPS operation.

Alarms Screen

How to view and manage active and historical alarms.

Settings Screen

Covers configuration of basic, system, battery, and communication settings.

Control Screen

Interface for controlling UPS operations like startup and shutdown.

About Screen

Displays UPS model, ESN, and software version information.

Operations

Checking Before Powering On the UPS

Essential checks before initial power-up of the UPS.

Single UPS Operations

Procedures for operating a single UPS unit.

Shutting Down the UPS

How to safely shut down the UPS inverter and system.

Performing EPO

Procedure for activating the Emergency Power Off function.

Parallel System Operations

Procedures for operating multiple UPS units in parallel.

Shutting Down the Parallel System

How to safely shut down multiple UPS units in a parallel system.

Performing EPO

EPO procedure for parallel UPS systems.

Communications

Optional Communications Components

Lists available optional communication modules for the UPS.

SNMP Card

Details the functions and features of the SNMP card.

Modbus Card

Details the functions and setup of the Modbus card.

Dry Contact Card

Details the functions and outputs of the Dry Contact card.

Routine Maintenance

UPS Maintenance

General maintenance tasks for the UPS and its components.

Battery Maintenance

Specific procedures and precautions for maintaining UPS batteries.

Troubleshooting

Technical Specifications

Physical Specifications

Dimensions, weight, and IP rating of the UPS models.

Environmental Specifications

Operating temperature, humidity, altitude, and storage conditions.

Mains Input Electrical Specifications

Electrical parameters for the UPS mains input.

Bypass Input Electrical Specifications

Electrical parameters for the UPS bypass input.

Output Electrical Specifications

Electrical parameters for the UPS output.

Battery Electrical Specifications

Electrical specifications related to the UPS batteries.

ECO Specifications

Specifications for the Economy Control Operation (ECO) mode.

Parallel System Specifications

Specifications related to parallel UPS system configurations.

Safety Regulations and EMC

Compliance with safety and electromagnetic compatibility standards.

Parallel Parameter List

UPS Differences

LCD Menus and Parameters

Alarm Handling

Cleaning or Replacing the Air Filter (6 kVA and 10 kVA)

Prerequisites

Conditions required before cleaning or replacing the air filter.

Procedure

Steps for cleaning or replacing the UPS air filter.

Alarm Handling of Battery Maintenance Notification

Context

Context for battery maintenance notifications.

Procedure

Steps to clear battery maintenance notification alarms.

Battery Shallow Discharge Test

Context

Context for performing a battery shallow discharge test.

Procedure

Steps to perform a battery shallow discharge test.

Battery Capacity Test

Context

Context for performing a battery capacity test.

Procedure

Steps to perform a battery capacity test.

Transferring the UPS That Has Generated an Alarm to Normal Mode and Clearing the Alarm Tone

Procedure

Steps to confirm an alarm and clear the alarm tone.

Acronyms and Abbreviations

Huawei UPS2000-G-10KRTL Specifications