EasyManua.ls Logo

HURST eDRAULIC SP 333 E2 - 8.3 Protective Equipment and Filter Checks

HURST eDRAULIC SP 333 E2
44 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
23
8.3 Protective equipment
Inspections to be carried out:
• Checktheprotectiveequipmentusedon/inthevicinityoftherescuedevice.Payparticular
attentiontotheprotectivecoverforthemovableparts(theremaybenocracks!).
Theairsuctionlteristobecheckedatleastonceayearorafteruseinadustyenvironment.
Thelter can be checked fromthe outside ifthe mainsunit (or battery)is removed(see
illustrationsbelow).
Ifthelterisseverelycontaminated,itwillneedtobereplaced.
Procedure:
1. Tilttherespectivedeviceasshownintheillustration.
2.Removethebatteryorthepowersupply.
3.Removetheltergridbyactivatingthereleasehook.
4.Replacethedirtylterelementswithnewlterelements.
8.4 Checking the lter in the battery shaft
Releasehook

Related product manuals