FILE MANAGER SECTION 3.6
3.6.3
VER.V09F
LOADING METIIOD 2: INTEL H1EX DATA FORMAT
Step All files must be converted into Intel Hex data format.
This is achieved with a standard CP/M utility program
(usually called UNLOAD) a version of which is reproduced
in section 9.5.4, PROGRAM 4 'UNLOAD'.
When converted you will have two copies of each file, one
in Intel Hex format:
MAIN.COM
OVERLAY ,OVR
PRODUCTS.TXT
MAIN.HEX
OVERLAY .HEX
PRODUCTS.HEX
Step 2 Set up the communications, see Part 6, COMMUNICATIONS.
Baud rate
Protocol
Parity
RTS
SERlG
Step 3 Load MAIN.COM
As required
NONE
As required
As required
OFF
Connect up HUNTER to the host computer with a suitable 5
way RS-232 cable. Then on HUNTER type:
>INP
After typing ENTER, HUNTER responds with
* Waiting
To abort use the ESC key.
If PIP is to be used to
transfer the file to HUNTER using the LST: printer
port, then type on the host computer
PIP LST:=MAIN.HEX
As soon as transmission begins, HUNTER responds with
* Loading
PAGE 3 - 45