The battery becomes
discharged too quickly.
Is specific gravity the
same in all cells of the
battery?
Does the generator
charge?
Replace the ignition
switch S9.
The engine does not
stop when the operator
rises from the seat.
Does the engine stop
when the ignition is
switched off?
Adjust or replace
microswitch S7 under the
operator’s seat.
No
No
No
Yes
Yes
Electrical system
TROUBLE SHOOTING
Applies to RBH 180, and RB 150 1996 and 1997 models
Applies to RBH 180, and RB 150 1996 and 1997 models
Replace relay K2 (the
lower one).
Yes
Replace the battery (6).
Replace the rectifier, fitted
on the right side of the
engine.