3-8 STARTUP / OPERATION
P/N 3141959_C U.S. & Canada 1-800-922-1919 • Mexico 1-800-890-2900 • www.hussmann.com
Discharge Air Sensor Location FNGSC6A
DETAIL A
SECURE DISCHARGE SENSOR WITH 0317371 CLAMP
& 0130711 SCREW SLFDRILL 8-18X12 HX
ADD 0399150 GASKET CHANNEL
TO SHAPR EDGES
LOCATE DISCHARGE SENSOR
ON THE LEFT SIDE DIMPLE
3023554
SENSOR-NTC 4 METER GREEN
B
DETAIL B
0257404 TUBE 3/8 ID VINYL
TO PROTECT SENSOR CABLE
(10 INCHES LONG)
SENSOR MUST NOT BE IN CONTACT
WITH COIL TUBES
K
K
8.50
3031571 SENSOR-NTC
4 METER ORANGE
USE TIE WRAP TO SECURE
SENSOR BELOW THE LOWEST
COIL TUBE
Defrost Sensor Location FNGSC6A