SECTION 3
Pr.12.6 Station ID (D = 1)
For polled data transfer, the unit must have a station number assigned to it in the
range of 1 – 31, which must be unique to the unit.
Text displayed
Description
12.6.1 StationID 01 Unique identification number for instrument
Pr.12.7
Sync Instrs Synchronise instruments (D = Master)
Options displayed
12.7.1 Sync Master
12.7.2 Sync Slave
This parameter is used in conjunction with Pr12.6 Station ID for synchronising two or
more instruments when they are in close proximity. See Appendix 6 for details, Page
64.
Pr.12.8
Check Search (D = Off)
Options displayed
Description
12.8.1 Check Search Off Check search not used
12.8.2 Check Search On Check search included
Check search should be used where fill rates can sometimes be greater than that
entered at Pr.5.0, or if the transducer is liable to be submerged.
Pr.12.9
Maximum gain (D = 100.0)
The maximum gain will be displayed in % and will be linear. It defines the level of
gain (power) available to the instrument when searching for a valid echo.
Pr.12.10
Serial Number (Viewable only)
This parameter displays the serial number of the Miniflex LR unit.
Pr.12.11
Revision Number (Viewable only)
Displays the Revision number of the software, e.g. LR 1.0.