MAINTENANCE
3-4 powermax30 Service Manual
Sequence of operation
Power OFF
• Connect the gas supply to the air fitting on the power
supply.
• Connect the work lead to the workpiece.
Apply power at the line-voltage disconnect box.
• Set the ON/OFF switch (S1) to ON (I)
Set the power switch (S1) to OFF (O).
• The gas solenoid valve (V1) closes.
• The gas flow stops.
• The arc extinguishes.
• Postflow continues for 20 seconds.
• Drag the torch lightly across the
workpiece to make a cut.
• The workpiece drops after the cut.
• Release the plasma start trigger on
the hand torch.
• The gas solenoid valve (V1) opens.
• The gas flow starts.
• The cutting arc starts.
• Position the torch on the workpiece.
• Pull the plasma start trigger on the torch.
The power circuits are ready.
• Set the amps adjustment knob to the desired output current
(between 15 and 30 amps) based on the input voltage and
circuit size.
• The green power ON LED illuminates, indicating the
system is ready for operation.
All the fault LEDs should be extinguished (see
Troubleshooting guide
for more information).

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hypertherm Powermax 30 and is the answer not in the manual?

Hypertherm Powermax 30 Specifications

General IconGeneral
BrandHypertherm
ModelPowermax 30
CategoryWelding System
LanguageEnglish

Related product manuals